Product Name: | Copper Knitted Wire Mesh | Material: | Copper Wire, C11000 Copper, Copper Content≥99.95% |
---|---|---|---|
Wire Numbers: | 1, 2, 3, 4 Wires | Shape: | Raschig Ring |
Processing: | Welding, Cutting | Application: | Filter |
Type: | Woven | Finish: | Bare, Tin-plating |
High Light: | 100FT Copper Knitted Wire Mesh,Blocker Copper Knitted Wire Mesh,knitted copper mesh for Stopper |
5"X100FT Roll 5Pcs Stainless Steel Mesh For Blocker Stopper Scrubber Copper Mesh
Material: | 99.9% Copper Wire | Wire Type: | Round Wire, Flat Wire |
---|---|---|---|
Mesh Width: | 4in, 5in, 6in, As Per Order | Other Name: | Copper Gauze |
Mesh Status: | Plain, Or Crimped | Strand Number: | 1, 2 Or 4. |
High Light: |
copper metal mesh,copper wire netting |
1. Copper mesh for pest control.
2. Copper mesh for demister fabricating.
As a kind of knitted wire mesh, copper mesh can also be used to make copper demisters, which are required in some special occasions.
Copper Wire Type |
Unit weight |
Specific area for same length copper mesh |
Specific area for same weight copper mesh |
Round wire Φ0.16mm |
a | b | c |
Round wire Φ0.23mm |
2.06a | 1.44b | 0.69c |
Flat wire 0.1*0.4mm |
1.99a | 1.99b | c |
3. Copper gauze for screw cleaning.
Steps to clean the screws and barrels efficiently with copper gauze and grease.
Step 1: Use a purging compound to clean the extruder. Then use small ball of copper mesh with some silicone grease on it to clean the die face. Also please clean the valve when it is still hot.
Step 2: Remove the die from the extruder head. It is best to clean it by silicone coated copper gauze forced through the die with a wooden dowel.
Step 3: Pull back and forth the copper gauze to complete the cleaning after it pass through the die.
Step 4: Make sure that no residual trace of adhered plastic is left, nor causing a scratch on the metal surface, so the die is thoroughly clean.
Step 5: Remove the hot screw partly, wrap the copper gauze with silicone coating 3 times around the screw, pull back and forth to do the cleaning.
Step 6: Keep sliding the copper gauze when removing the screw out of barrel slowly, until the screw is clean. It takes only 5 minutes for step 5 and 6 operations.
Step 7: Wrap copper mesh at end of a long rod and pass it through the barrel. Then, chuck the rod into power drill, insert fresh gauze and pass back and forth through barrel until clean.
Step 8: Please do all the operations with silicone grease coated copper mesh. Now all parts is clean and ready for reassemble.